Finishing The System: This pump is supplied complete with gaskets and hardware but without the inlet fitting. The fitting needs to be ordered according to the size of the lower radiator hose.
Amperage draw: Under normal use the pump will draw 6-7 amps.
Overall Height Dimension: The standard pump is 5.79" long from the mounting surface to the tip of the pump.
Heavy duty option adds .5" in length
Pump Weight: This application weighs 8.8 lbs.
16 volt systems: The 12 volt pump will work for limited use applications. The pump should not be powered while charging your 16 volt system.
Additional Notes: The standard 35 GPM pump is suitable for normally aspirated engines up to 650HP. Supercharged, Turbocharged and high compression, high horsepower applications should use the 55GPM High Flow pump only.